Fox H1-4.6-E-G2 AC1-4.6-E-G2 Single-Phase Hybrid/AC Inverter with Battery Pack EP 5
INPUT PV (ONLY FOR HYBRID)
Max. Input Power [W]: 6900 A:3450 B:3450
Max. Input Voltage [V]: 600
Start-up Input Voltage [V]: 75
Rated Input Voltage [V]: 360
MPPT Operating Voltage Range [V]: 80 ~ 550
Max. Input Current [A]: 16 / 16
Max. Short-circuit Current [A]: 20 / 20
No. of Independent MPP Trackers: 2
No. of Strings per MPP Tracker: 1
BATTERY CONNECTION
Battery Type: Lithium Battery (LFP)
Battery Voltage [V]: 80 ~ 480
Max. Charge/Discharge Current [A]: 40
Communication Interface: CAN (communicate with inverter, upgrade BMS)
AC INPUT AND OUTPUT (GRID)
Max. AC Input Power [VA]: 9200
Max. AC Input Current (per phase) [A]: 41.8
Rated Output Power [W]: 4600
Max. Output Apparent Power [VA]: 5060
Rated Output Current (per phase) [A]: 20.9
Rated Output Current (per phase) [A] (For AUS): 20.0
Max. Output Current [A]: 23.0
Rated Grid Voltage [V]: 220/230/240
Rated Grid Frequency [Hz]: 50/60
Power Factor: 1 (Adjustable from 0.8 leading to 0.8 lagging)
THDi [%]: <3 @rated power
EPS OUTPUT (WITH BATTERY)
Max. Output Apparent Power [VA]: 4600
Peak Output Apparent Power (60s) [VA]: 5500
Max. Current (per phase) [A]: 20.9
Rated Output Voltage [V]: 220/230/240
Rated Output Frequency [Hz]: 50/60
Power Factor: 1 (Adjustable from 0.8 leading to 0.8 lagging)
THDv (linear Load) [%]: <2 @rated power
Parallel operation [PCS]: 10
Switch time [ms]: <20
EFFICIENCY
Euro Efficiency [%]: 96.23
Max. Efficiency [%]: 97.04
Max. Battery Charge Efficiency (PV to BAT) (@full load) [%]: 98.50
Max. Battery Discharge Efficiency (BAT to AC) (@full load) [%]: 97.00
PROTECTION
Insulation Monitoring: YES
Residual Current Monitoring: YES
DC Reverse Polarity Protection: YES
Anti-islanding Protection: YES
AC Short-circuit Protection: YES
AC Overcurrent/Overvoltage Protection: YES
DC Switch: YES
Battery Wack-up Function: YES
SPD: DC: Type II, /AC: Type III
AFCI: Optional
GENERAL DATA
Dimensions (W*H*D) [mm]: 434*418*185
Weight [kg]: 22
Installation: Wall-Mounted
Topology: Non-isolated
Cooling Method: Natural
Noise Emission [dB]: 35
Max. Operating Altitude [m]: 2000
Operating Temperature Range [°C]: -25 ~ 60
Humidity (No Condensation) [%]: 0 ~ 100
Ingress protection: IP65
Standby consumption[W]: <15
Monitoring Module: WiFi, LAN(Optional) , 4G(Optional)
Communication: RS485, DRM, Ripple Control, USB, CAN
Display: LCD, App, Website
STANDARD COMPLIANCE (MORE AVAILABLE UPON REQUEST)
Safety: EN 62109-1, EN 62109-2
Grid Regulation: AS / NZS 4777.2
Reviews